− 17 −
4-7. Outdoor Unit (RAS-10UA-E3)
No. Parts name Type Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220 − 240 V, 50Hz
1 Compressor PH102T1-4CH Winding resistance (Ω)C-RC-S
(at 20°C) 3.17 5.18
Output (Rated) 20 W, 6 poles, 1 phase, 220 − 240 V, 50Hz
2 Fan motor (for outdoor)
HF-240-20B or
Winding resistance (Ω) Red-Black White-Black
(at 20°C)
387.3 or 235.2
466.2 or 260.1
3
Running capacitor
DS451155BPQC AC 450 V, 1.5 F
(for fan motor)
4
Running capacitor
DS371256CPNB AC 370 V, 25 F
(for compressor)
μ
μ
SKF-240-20B
387.3 or 235.2 466.2 or 260.1
No. Parts name Type Specifications
Output (Rated) 560W, 2poles, 1 phase, 220 − 240V, 50Hz
1 Compressor PH80T1-4C Winding resistance (Ω)C-RC-S
(at 20°C) 4.80 8.37
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
2 Fan motor (for outdoor) Winding resistance (Ωı) Red-Black White-Black
(at 20°C)
3
Running capacitor
DS451155CBPQC AC 450V, 1.5μˇF
(for fan motor)
4
Running capacitor
DS371156CPNB AC 370V, 15μˇF
(for compressor)
5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
4-8. Outdoor Unit (RAS-07UA-E3)
HF-240-20B or
SKF-240-20B
FILE NO. SVM-04022