4-6. Outdoor Unit (RAS-10UA-ES4)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance () C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor)
HF-240-20B or
Winding resistance (Ω) Red-Black White-Black
(at 20°C) 387.3 or 235.2 466.2 or 260.1
3
Running capacitor
DS451155NPQB AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
DS441256CPNAL AC 440V, 25µF
(for compressor)
4-5. Indoor Unit (RAS-13UKP-ES4, RAS-10UKP-ES4, RAS-07UKP-ES4)
No. Parts name Type Specifications
1 Fan motor (for indoor)
SKF-220-20-4A-1
AC Motor with 150°C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25°C
3
Transformer
TT-10
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
10k at 25°C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600V
8 Capacitor (C50) PF1E222MNN1625 2200µF, 25V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10
V
aristor (R21, R22) 15G561K320 560V
11
Louver motor
MP24Z
12VDC
12
Relay (Comp., RY01) DI1U
Rating 25A/AC250V, 3~48VDC
SKF-240-20B
FILE NO. SVM-05020

Table of Contents