27 EN
FRANÇAISDEUTSCHSVENSKAРУССКИЙ ЯЗЫКSUOMIDANSKNORSK ENGLISH
• These specifications are subject to change without notice for the purpose of incorporating technical improvements.
The specified air-conditioning performance is based on the data determined under the following conditions.
INFORMATIONINFORMATION
When the outside temperature drops, power is supplied to the de-icing heater of the outdoor unit even if the air conditioner is off. At
this time the power consumption is approximately 100 W.
SPECIFICATIONS
Ty pe Reverse cycle, Split type
Model Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
RAS-10SKVP-ND RAS-10SAVP-ND RAS-13SKVP-ND RAS-13SAVP-ND
Power supply 220–240 V ~50 Hz 220–240 V ~50 Hz
Cooling capacity (kW) CAPA. 2.5 3.5
Heating capacity (kW) CAPA. 3.2 4.2
Cooling current (A) AMP. 0.15 2.57–2.34 0.15 4.00–3.66
Cooling power (W) WATT. 30 460 30 820
Heating current (A) AMP. 0.15 3.15–2.87 0.15 4.40–4.02
Heating power (W) WATT. 30 600 30 920
Dimensions
Width (mm) 790 780 790 780
Height (mm) 250 550 250 550
Depth (mm) 208 290 208 290
Net weight (kg) 9 38 9 38
Ty pe Reverse cycle, Split type
Model Indoor Unit Outdoor Unit
RAS-16SKVP-ND RAS-16SAVP-ND
Power supply 220–240 V ~50 Hz
Cooling capacity (kW) CAPA. 4.5
Heating capacity (kW) CAPA. 5.5
Cooling current (A) AMP. 0.15 6.18–5.65
Cooling power (W) WATT. 30 1,320
Heating current (A) AMP. 0.15 6.83–6.25
Heating power (W) WATT. 30 1,460
Dimensions
Width (mm) 790 780
Height (mm) 250 550
Depth (mm) 208 290
Net weight (kg) 9 38
For cool
ng
Air inlet temperature °C
Indoor coil assembly Outdoor coil assembly
Dry bulb Wet bulb Dry bulb Wet bulb
27 19 35 24
Air inlet temperature °C
Indoor coil assembly Outdoor coil assembly
Dry bulb Wet bulb Dry bulb Wet bulb
20 — 7 6
A1YPGTU/CPWCNA'0HO2CIG9GFPGUFC[,CPWCT[2/