2-2. Operation Characteristic Curve
5
<Cooling> <Heating>
0
1
2
3
4
5
6
7
8
0 102030405060708090100110120
Compressor Speed (rps)
Current (A)
0
1
2
3
4
5
6
7
8
0 102030405060708090100110120
Compressor Speed (rps)
Current (A)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C
Air Flow : High
Pip Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Air Flow : High
Pip Length : 5m
Voltage : 230V
2-3. Capacity Variation Ratio According to Temperature
<Cooling>
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Outdoor temp. (℃)
Capacity ratio (%)
Conditions
Indoor:DB27℃/WB19
Indoor air flow:High
Pipe length:5m
<Heating>
0
20
40
60
80
100
120
-15 -10 -5 0 5 10
Outdoor temp. (℃)
Heating Capacity ratio (%)
Condition
Indoor:DB20
Indoor air flow:High
Pipe length:5m
Capacity ratio 100% is 3500kw
Capacity ratio 100% is 4200kw
Capacity ratio 100% is 3500kw