– 17 –
5-4. RAS-10UK-ES3 / RAS-10UA-ES3
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan
Outdoor unit
PA108X1T-4FZ1
Cooling
Mark ( ) means check points of Gas Leak.
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
(∅9.52)
Packed valve
(∅6.35)
0.39 m
(Connecting pipe)
∅9.52
0.49 m
(Connecting pipe)
∅6.35
T1
P
Refrigerant
R410a : 0.65
kg.
Evaporator
Capillary tube
∅1.5 x 1100
l
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.95 11.0 High 27/19 35/24
Cooling Overload 1.15 15.0 High 32/23 43/26
Low temperature 0.85 5.0 Low 21/15 21/15
Standard
pressure
P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
50Hz
Note
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
FILE NO. SVM-04017