Table 9-6-2 Approximate resistance value of thermo sensor
Temperature 0°C
Resistance value 33.8 20.35 12.59 10.00 7.99
(k )
10°C
20°C
25°C
30°C
MODE
AUTO
COOL
FAN
TEMP.
TEMP.
START/STOP
SWING
MODE
TIMER
ON OFF SET CLR
ECO
RST
CHK
FIX
FAN
AUTO
QUIET
AUTO FAN
DRY
Hr.ON OFF
WC-K3JE
B
[CHK] button
[CLR] button
9-6-2. How to shorten time of restart delay timer
(1) Set the operation mode, temperature, and air flow
code + timer short code.
(3) Pushing [START/STOP] buttons sends operation
are released.)
(The status is kept even if [CHK] and [CLR] buttons
and the timer short mode is waited.
pushed in this case, the check mode is released,
(2) Push the [CLR] button while keeping [CHK] button
rate to be applied with the timer short mode.
(4) The timer short mode is released by only a trans-
mission. Therefore, repeat steps from (2) to
perform the timer short mode again.