4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13UKHP-ES3, RAS-13UKHP-AS3, RAS-10UKHP-ES3,
RAS-10UKHP-AS3)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 mo fuse
2 Thermo sensor (T
3 Switching transformer (T01) SWT-47
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270
7 Bridge rectifier (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µˇ F, 400V
9 Fuse (F01) TSCR6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6Ω, 2W
12 Louver motor MP24Z 12VDC
13 Relay (Comp., RY01) DI12D1 Rating 20A/AC250V, 12VDC
14 Relay (Fan, RY03) G5N-1A Rating 3A/AC250V, 12VDC
15 Relay (Solenoide, RY04) G5N-1A Rating 3A/AC250V, 12VDC
4-2. Outdoor Unit (RAS-13UAH-ES3, RAS-13UAH-AS3)
No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 − 240V, 50Hz
1 Compressor PA150X2T-4FM1 Winding resistance (Ωı) C-R C-S
(at 20°C) 2.49 3.95
Output (Rated) 42W, 6poles, 1 phase, 220 − 240V, 50Hz
2 Fan motor (for outdoor) HF-240-42A Winding resistance (Ω) Red-Black White-Black
(at 20°C) 176.2 290.5
3
Running capacitor
DS451155BPQC AC 450V, 1.5µˇF
(for fan motor)
4
Running capacitor
DS371306CPNB AC 370V, 30µˇF
(for compressor)
Solenoid coil
5 (for 4-way valve) VHV-01AJ503C1 AC 220 − 240V, 50Hz
(for Heat pump model)
AC Motor with 150°C ther
A-sensor) 10kΩ at 25°C
10kΩ at 25°C
27mH, 600mA
ΩΩ