Summary

Preparation Before Use

Air Flow Direction

Remote Control

Automatic Operation

Cooling Heating Fan Only Operation

Dry Operation

Timer Operation

Auto Restart Operation

Maintenance

Indoor Unit and Remote Control

Instructions for cleaning the indoor unit and remote control.

Self Cleaning Operation

Operation and Performance

Troubleshooting

Remote Control A-B Selection

Overview

This document serves as the owner's manual for a Toshiba R32 Inverter Air Conditioner (Split Type), designed for general public use. It covers indoor units RAS-10, 13, 16PKVSG-E and outdoor units RAS-10, 13, 16PAVSG-E. The manual emphasizes safety precautions, operational procedures, and maintenance guidelines to ensure safe and efficient use of the appliance.

Safety Precautions:

The manual begins with crucial safety information, categorized as DANGER, WARNING, and CAUTION, highlighting the importance of reading and understanding these precautions before operation. It states that the appliance is filled with R32 refrigerant and advises keeping the manual accessible.

DANGER warnings include:

  • Do not install, repair, open, or remove the cover, as this may expose users to dangerous voltages. Such tasks should only be performed by a dealer or specialist.
  • Turning off the power supply alone will not prevent potential electric shock.
  • The appliance must be installed according to national wiring regulations, with a disconnection means having a contact separation of at least 3 mm in all poles incorporated into the fixed wiring.
  • The appliance must be stored in a room free from continuously operating ignition sources (e.g., open flames, operating gas appliances, or electric heaters).
  • Do not operate the unit when harmful gases (flammable or corrosive) are detected nearby to prevent fire, explosion, or injury.

WARNING warnings include:

  • Avoid prolonged direct exposure to cool or warm air.
  • Do not insert fingers or any objects into the air inlet/outlet.
  • In case of abnormality (e.g., burning smell), stop the air conditioner and disconnect the power supply or turn off the breaker.
  • The appliance can be used by children aged 8 and above, and by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge, provided they receive supervision or instruction on safe use and understand the associated hazards. Children should not play with the appliance, and cleaning/user maintenance should not be performed by children without supervision.
  • The appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless supervised by a person responsible for their safety.
  • Installation, maintenance, repair, and removal of the air conditioner must be carried out by a qualified installer or service person.
  • Do not use any refrigerant other than R32 for complement or replacement, as this could lead to abnormally high pressure in the refrigeration cycle, potentially causing product failure, explosion, or injury.
  • Do not use means to accelerate defrosting or cleaning other than those recommended by the manufacturer.
  • Be aware that refrigerants may not have an odor.
  • Do not pierce or burn the appliance, as it is pressurized. Avoid exposing it to heat, flames, sparks, or other ignition sources, as it may explode and cause injury or death.
  • The appliance and pipe-work must be installed, operated, and stored in a room with a floor area larger than A_min m². The manual provides a formula to calculate A_min based on refrigerant charge and installation height.

CAUTION warnings include:

  • Do not wash the unit with water, as this may cause electric shock.
  • Do not use the air conditioner for purposes other than its intended use, such as preserving food or breeding animals.
  • Do not step or place objects on the indoor/outdoor unit to prevent injury or damage.
  • Avoid touching the aluminum fin, as it may cause injury.
  • Turn off the main switch or circuit breaker before cleaning the unit.
  • If the unit will not be used for a long time, turn off the main switch or circuit breaker.
  • Regular maintenance by a specialist is recommended for units operated for extended periods.
  • The manufacturer disclaims liability for damage caused by not observing the instructions in this manual.

Function Description:

Indoor Unit Display:

The indoor unit features a display with indicators for:

  • Eco (White)
  • Hi-Power (White)
  • Timer (White)
  • Operation mode: Cool (Blue) and Heat (Orange). Display brightness can be adjusted.

Preparation Before Use:

  • Preparing Filters: Instructions for opening the air inlet grille, removing, attaching, and cleaning air filters.
  • Loading Batteries: For wireless operation, remove the slide cover, insert two AAA batteries according to polarity, and replace the cover.
  • Clock Setup: Use a pencil to push the CLOCK button, then adjust the time using the ON/OFF buttons and set with the SET button.
  • Remote Control Reset: Reset the remote control by pushing the RESET button with a pencil, or by removing and reinserting batteries after pressing the power button.

Air Flow Direction:

  • Vertical Direction: Press the FIX button to move the louver to the desired vertical position.
  • Swing Function: Press the SWING button to initiate automatic louver swing and press again to stop.
  • Horizontal Direction: Adjust manually.
  • Note: Do not manually move the louver, as its automation positioning may be affected by some operation modes.

Remote Control:

The remote control is a wireless type that can also be used as a wired control. It features:

  • Infrared signal emitter
  • Start/Stop button
  • Mode select button (MODE)
  • Temperature button (TEMP)
  • Fan speed button (FAN)
  • Swing louver button (SWING)
  • Set louver button (FIX)
  • On timer button (ON)
  • Off timer button (OFF)
  • Setup button (SET)
  • Clear button (CLR)
  • Memory and Preset button (PRESET)
  • One-Touch button (ONE-TOUCH)
  • High power button (Hi-POWER)
  • Economy button (ECO)
  • Quiet button (QUIET)
  • Comfort sleep button (COMFORT SLEEP)
  • Filter reset button (FILTER)
  • Set clock button (CLOCK)
  • Check button (CHECK)
  • Reset button (RESET) In wired operation, the remote controller returns to initial conditions (PRESET, TIMER, CLOCK) if the air conditioner's power supply is shut down.

One-Touch Operation:

Pressing the ONE-TOUCH button initiates a fully automated operation tailored to typical consumer preferences in the region. This feature controls temperature, airflow strength, direction, and other settings.

Automatic Operation:

To automatically select cooling, heating, or fan-only operation:

  • Press MODE to select "A" (Auto).
  • Press TEMP to set the desired temperature.
  • Press FAN to select AUTO, LOW, LOW+, MED, MED+, or HIGH fan speeds.

Cooling / Heating / Fan Only Operation:

  • Press MODE to select Cool, Heat, or Fan only.
  • Press TEMP to set the desired temperature (Cooling: Min. 17°C, Heating: Max. 30°C; Fan Only: No temperature indication).
  • Press FAN to select AUTO, LOW, LOW+, MED, MED+, or HIGH fan speeds.

Dry Operation:

For dehumidification, a moderate cooling performance is automatically controlled.

  • Press MODE to select Dry.
  • Press TEMP to set the desired temperature.

Hi-Power Operation:

To automatically control room temperature and airflow for faster cooling or heating (except in DRY and FAN ONLY mode):

  • Press HI POWER to start and stop the operation.

Eco Operation:

To automatically control room to save energy (except in DRY and FAN ONLY mode):

  • Press ECO to start and stop the operation.
  • Note: In cooling operation, the set temperature increases automatically by 1 degree/hour for 2 hours (maximum 2 degrees increase). In heating operation, the set temperature decreases.

Temporary Operation:

If the remote control is misplaced or discharged:

  • Pressing the RESET button on the indoor unit allows the unit to start or stop.
  • Operation mode is set to AUTOMATIC, preset temperature to 24°C, and fan operation to automatic speed.

Timer Operation:

Set the timer when the air conditioner is operating.

  • Setting the ON Timer: Press ON to set the desired ON timer, then press SET.
  • Setting the OFF Timer: Press OFF to set the desired OFF timer, then press SET.
  • Canceling Timers: Press CLR to cancel the timer.
  • Daily Timer: Allows setting both ON and OFF timers, which activate daily.

Display Lamp Brightness Adjustment:

To decrease display lamp brightness or turn it off:

  • Press and hold FAN for 3 seconds until brightness level (d0, d1, d2, or d3) is shown on the remote control LCD.
  • Press TEMP. Rise or TEMP. to adjust brightness in 4 levels (100%, 50%, 50% with operation lamp off, all lamps off).

Preset Operation:

Set preferred operation for future use. The setting will be memorized (except airflow direction).

  • Select preferred operation.
  • Press and hold PRESET for 3 seconds to memorize the setting (the mark displays).
  • Press PRESET to operate the preset operation.

Auto Restart Operation:

To automatically restart the air conditioner after a power failure (unit must be on).

  • Setting: Press and hold the RESET button on the indoor unit for 3 seconds (3 beep sounds, OPERATION lamp blinks 5 times/sec).
  • Canceling: Press and hold the RESET button on the indoor unit for 3 seconds (3 beep sounds, OPERATION lamp does not blink).
  • Note: Auto Restart Operation does not activate if ON or OFF timers are set.

Quiet Operation:

To operate at super low fan speed for quiet operation (except in DRY mode):

  • Press QUIET to start and stop the operation.
  • Note: Quiet operation may not provide adequate cooling due to low sound features.

Comfort Sleep Operation:

For comfortable sleep, automatically controls airflow and turns OFF.

  • Press COMFORT SLEEP to select 1, 3, 5, or 9 hours for OFF timer operation.
  • Note: In cooling operation, the set temperature increases automatically by 1 degree/hour for 2 hours (maximum 2 degrees increase). In heating operation, the set temperature decreases.

Maintenance Features:

Maintenance:

Always turn off the circuit breaker first.

  • Indoor Unit and Remote Control: Clean with a wet cloth when needed. Do not use benzine, thinner, polishing powder, or chemically-treated duster.
  • Air Filters: Clean every 2 weeks.
    1. Open the air inlet grille.
    2. Remove the air filters.
    3. Vacuum or wash and then dry them.
    4. Reinstall the air filters and close the air inlet grille.

Self Cleaning Operation (Cool and Dry Operation Only):

To prevent bad smells caused by humidity in the indoor unit:

  • If the button is pressed once during "Cool" or "Dry" mode, the fan will continue to run for 30 minutes, then turn off automatically, reducing moisture.
  • To stop the unit immediately, press the button two more times within 30 seconds.

Operation and Performance:

  • Three-minute protection feature: Prevents unit activation for 3 minutes after sudden restart or switching ON.
  • Preheating operation: Warms up the unit for 5 minutes before heating operation starts.
  • Warm air control: When room temperature reaches the set temperature, fan speed reduces, and the outdoor unit stops.
  • Automatic defrosting: Fans stop during defrost operation.
  • Heating capacity: Heat is absorbed from outdoors and released into the room. If outdoor temperature is too low, use another heating apparatus.
  • Consideration for accumulated snow: Select an outdoor unit position not subjected to snow drifts, leaf accumulation, or other seasonal debris.
  • Minor cracking sound: May occur due to expansion/contraction of plastic.

Air conditioner operating conditions:

The manual provides a table outlining the recommended outdoor and room temperatures for Heating, Cooling, and Dry operations.

Troubleshooting (Check Point):

  • Unit does not operate: Check if the power main switch is off, circuit breaker is activated, electric current stopped, or ON timer is set.
  • Cooling or Heating is abnormally low: Check if filters are blocked, temperature is set improperly, windows/doors are open, outdoor unit air inlet/outlet is blocked, fan speed is too low, or operation mode is FAN or DRY.

Remote Control A-B Selection:

To use separate remote controls for two indoor units installed nearby:

  • Remote Control B Setup:
    1. Press the RESET button on the indoor unit to turn it ON.
    2. Point the remote control at the indoor unit.
    3. Push and hold the CHECK button with a pencil (00 will be shown).
    4. Press MODE while pushing CHECK (B will show, 00 will disappear, and the air conditioner will turn OFF). Remote Control B is memorized.
  • Note: Repeat steps to reset Remote Control to A. Remote Control A does not have an "A" display. Default setting is A.

Toshiba RAS-16PKVSG-E Specifications

General IconGeneral
Power Supply220-240V, 50Hz
RefrigerantR32
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
Indoor Unit Weight9 kg
TypeSplit Type
Cooling Capacity1.6 kW
Heating Capacity1.8 kW
Noise Level (Indoor)21 dB
Noise Level (Outdoor)49 dB