1
Press 
FIX
 : Move the louver in the 
desired vertical direction.
2
Press 
SWING
 : Swing the air 
automatically and press again to stop.
3
For horizontal direction, adjust 
manually.
 
DANGER
•
  Do not install, repair, open or remove the cover. It may expose you 
to dangerous voltages. Ask the dealer or the specialist to do this.
•
  Turning off the power supply will not prevent potential electric 
shock.
•
  The appliance shall be installed in accordance with national wiring 
regulation.
•
 Means for disconnection from the supply having a contact 
separation of at least 3 mm in all poles must be incorporated in the 
fi xed wiring.
 
WARNING
•
  Do not expose your body directly to cool air for a long time.
•
  Do not insert your fi nger or any article into the air inlet/outlet.
•
  When an abnormality (burning smell, etc.) occurs, stop the air 
conditioner and disconnect the power supply or turn off the 
breaker.
 
CAUTION
•
  Do not wash the unit with water. It may cause an electric shock.
•
  Do not use this air conditioner for other purposes such as 
preserving food, breeding animal, etc.
•
  Do not step or put anything on the indoor/outdoor unit. It may 
cause an injury or damage the unit.
•
  Do not touch aluminium fi n because it may cause an injury.
•
  Before cleaning the unit, turn off the main switch or the circuit 
breaker.
•
  When the unit won’t be used for a long time, turn off the main 
switch or the circuit breaker.
•
  It is recommended that maintenance be performed by a specialist 
when the unit has been operated for a long time.
PRECAUTIONS FOR SAFETY
INDOOR UNIT DISPLAY
1  Hi POWER (Green)
2  FILTER (Orange)
3  PURE (Blue) (10, 13, 16SKVR-E Series)
3 
FAN-ONLY (Orange) 
 (M10, 13, 16SKCV-E Series)
3 PRE DEF (DE-FROST) (Orange) 
 (13, 16SKV-E, M10, 13, 16SKV-E Series)
4  TIMER (Yellow)
5  OPERATION (Green)
6  RESET button
1
Hi POWER FILTER PURE TIMER OPERATION
RESET
12
3
45
6
PREPARATION BEFORE USE
2
Preparing Filters
  1. Open the air inlet grille and remove the air fi lters.
 2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
  1. Remove the battery cover. 
  2. Insert 2 new batteries (AAA type) 
    following the (+) and (–) positions.
Clock Setup
  1. Push CLOCK 
●
 by tip of the pencil.
 2. Press 
ON
 or 
OFF
: adjust the time.
 3. Press 
SET
 : Set the time.
Remote Control Reset
  1. Remove the battery.
 2. Press 
.
  3. Insert the battery.
AIRFLOW DIRECTION
3 
  •  Do not move the louver manually by others.
  •  The louver may automation positioning by come operation mode.
Note:
REMOTE CONTROL
4  
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHK
CLOCK
OFF
CLR
SLEEP
SET
FIX Hi-POWER ECO
PURE
COMFORT
SLEEP
MODE
TEMP
FAN
5
4
3
~
(
&
9
-
"
#
$
%
)
,
.
8
7
6
+
1
1  Infrared signal emitter
2  Start/Stop button
3  Mode select button (MODE)
4  Temperature button (TEMP)
5  Fan speed button (FAN)
6  Swing louver button (SWING)
7  Set louver button (FIX)
8  On timer button (ON)
9  Off timer button (OFF)
!  Sleep timer button (SLEEP)
"  Setup button (SET)
#  Clear button (CLR)
$  Memory and Preset button (PRESET)
%  One Touch button (ONE-TOUCH)
&  High power button (Hi-POWER)
(  Economy button (ECO)
)  Quiet button (QUIET)
~  Comfort sleep button (COMFORT SLEEP)
+  Plasma Air Purifi er button (PURE)
 (RAS-10, 13, 16SKVR-E Only)
,  Filter reset button (FILTER)
-  Clock Reset button (CLOCK)
.  Check button (CHK)
ONE-TOUCH
5
Press the “ONE-TOUCH” button for fully automated operation that is customised 
to the typical consumer preferences in your region of the world. The customised 
settings control temperature air fl ow strength, air fl ow direction and other settings 
to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer 
other settings you can select from the many other operating functions of your 
Toshiba unit.
 Press 
ONE-TOUCH
: Start the operation.
AUTOMATIC OPERATION
6
To automatically select cooling, heating, or fan only operation
1. Press 
MODE
 : Select A.
2. Press 
TEMP
  : Set the desired temperature.
COOLING / HEATING / FAN ONLY OPERATION
7
1. Press 
MODE
  : Select Cool  , Heat  , or Fan only  .
2. Press 
TEMP
 : Set the desired temperature.
 Cooling: Min. 17
o
C, Heating: Max. 30
o
C, Fan Only: No temperature indication
3. Press 
FAN
 : Select AUTO, LOW  , LOW+  , MED  , MED+  , or  
 HIGH  .
DRY OPERATION (COOLING ONLY)
8
For dehumidifi cation, a moderate cooling performance is controlled 
automatically.
  1. Press 
MODE
 : Select Dry  .
 2. Press 
TEMP
 : Set the desired temperature.
AIR PURIFYING OPERATION 
(RAS-10, 13, 16SKVR-E Only)
9
During air conditioner operation
 Press 
PURE
 to start and stop plasma air purifi er and air ionizer operation.
The plasma air purifi er and air ionizer can be activated or deactivated during air 
conditioner is stopped and the air ionizer starts in conjunction with plasma air 
purifi er operation.
Note: The FILTER indicator (orange) turns on after PURE operation is performed 
for about 1000 hours.
2
A
C
L
Hi-POWER OPERATION
10
To automatically control room temperature and airfl ow for faster cooling or heating 
operation (except in DRY and FAN ONLY mode)
 Press 
Hi-POWER
: Start and stop the operation.
ECO OPERATION
11
To automatically control room to save energy (except in DRY and FAN ONLY 
mode)
 Press 
ECO
 : Start and stop the operation.
Note:  Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the 
set temperature will decrease.
CLEANING
RESET TIMER OPERATION
32 1
1  OPERATION (Green)
2  TIMER/CLEANING (Yellow)
3  RESET button
Models: RAS-10, 13, 16SKV(R) Series, RAS-M10, 13, 16SK(C)V Series,
Models: RAS-10SKV-E
!
Owner 1110250125.indb   2Owner 1110250125.indb   2 12/24/07   10:48:21 AM12/24/07   10:48:21 AM