– 25 –
7-2. Operation Data
<Cooling>
<Heating>
Tempeature Model name Standard Heat exchanger Indoor Outdoor Compressor
condition(°C) RAS- pressure pipe temp. fan mode fan mode revolution
Indoor Outdoor P (MPa) T1 (°C) T2 (°C) (rps)
27/19 35/- B10UFV-E 0.9 to 1.1 12 to 14 41 to 43 High High 49
B13UFV-E 0.8 to 1.0 10 to 12 39 to 41 High High 74
B18UFV-E 0.8 to 1.0 8 to 10 37 to 39 High High 77
Tempeature Model name Standard Heat exchanger Indoor Outdoor Compressor
condition(°C) RAS- pressure pipe temp. fan mode fan mode revolution
Indoor Outdoor P (MPa) T1 (°C) T2 (°C) (rps)
20/- 7/6 B10UFV-E 2.1 to 2.3 37 to 39 2 to 4 High High 62
B13UFV-E 2.4 to 2.6 41 to 43 1 to 3 High High 84
B18UFV-E 2.9 to 3.0 49 to 51 1 to 3 High High 75
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m (10k, 13k) and 7.5 m (18k)