FILE NO. SVM-04032
47
8-4-5. Console installation
Select the terminal of Selector-SW from [C position] to
[F position].
Fig. 8-4-18
<Cutting a hole and mounting the installation plate>
When installing the rear piping, determine the pipe
hole position, drill the pipe hole (80 mm) at a slight
downward slant to the outdoor side.
For mounting of the Installation plate 1, use the Paper
pattern, which is inside the package box cover.
Fig. 8-4-19
Fig. 8-4-20
CAUTION
Failure to firmly install the unit may result in personal
injury and property damage if the unit falls.
In case of block, brick, concrete or similar type walls,
make 5 mm dia. holes in the wall.
Insert clip anchors for appropriate Mounting screws 8.
NOTE:
Secure four corners and lower parts of the Installation
plate 1 with 6 to 8 mounting screws to install it.
390 mm
or more
375 mm
or more
Rear piping hole. 80
Floor
REMOCON
INSTALL
A
C
B
F
140
633
320
160
742
1093
60
Projection
15 mm or less
88
88
8 Mounting
screw
4 x 25
ss
ss
s
Clip anchor
(local parts)
5 mm dia. hole
Anchor bolt
<Install the indoor unit>
Install the Installation plate 1 at the wall according to
the Paper pattern .
Hang the indoor unit on the hooks of the Installation
plate 1.
Fix the lower portion of the indoor unit with Mounting
screws 8 (2 places).
Fig. 8-4-21
<Condition for installation>
The unit must not decline more than 15 mm in either
axis.
Fig. 8-4-22
Indoor unit
Hook
11
11
1 Installation
plate
88
88
8 Mounting screw
15 mm
88
88
8 Mounting screw