Do you have a question about the Toshiba RAS-35SKVP2-ND and is the answer not in the manual?
Brand | Toshiba |
---|---|
Model | RAS-35SKVP2-ND |
Category | Air Conditioner |
Language | English |
Safety precautions for handling R410A refrigerant during installation.
Guidelines for installing refrigerant piping using copper pipes and joints.
Guidelines for connecting flare pipes, including tightening torque.
Lists tools required for R410A installation and general tools.
Step-by-step procedure for recharging refrigerant into the system.
Procedures and precautions for brazing, including preventing oxidation.
General installation steps and considerations.
Procedures for cutting holes and mounting the installation plate for the indoor unit.
Information on power supply voltage and connection methods to the main circuit breaker.
Procedures for forming refrigerant piping and drain hoses, including insulation.
Steps for physically mounting the indoor unit onto the installation plate.
Instructions for running the drain hose to ensure proper drainage.
Guidelines for selecting an appropriate installation location for the outdoor unit.
Procedure for installing drain nipples and waterproof caps for defrost water drainage.
Steps for flaring copper pipes for refrigerant piping connections.
Procedure for evacuating air from the refrigerant pipes using a vacuum pump.
Instructions for connecting the power cord and connecting cable to the outdoor unit.
Procedure for replacing temperature sensors, including common service parts.
Interpreting flashing LED patterns for self-diagnosis of the indoor unit.
Using the remote controller for self-diagnosis and retrieving check codes.
Troubleshooting based on observed symptoms of the indoor unit.
Diagnosing troubles related to the indoor unit and remote controller operation.
Troubleshooting steps specific to the indoor fan motor not operating.
Diagnosing why the indoor fan motor starts automatically upon power supply.
Steps to diagnose and resolve issues with the remote controller.
Diagnosing issues related to wiring failures between indoor and outdoor units.
Interpreting check codes 1C and 1E related to wiring and discharge errors.
Flowchart for diagnosing troubles within the outdoor unit.
Procedure to check the functionality of the air purifier.
Procedure to check the functionality of the minus ion generator.
Procedure to check the main parts of the unit.
Procedure to diagnose the condition of the outdoor fan motor.
Procedure for installing the cross flow fan.