6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-12061
– 18 –
6-1. Indoor Unit
6-2. Outdoor Unit
No.
Parts name Type Specifications
MF-340-30-3
AC 240V, 20W
2 Room temp. sensor (TA-sensor) ( - ) 10kΩ at 25°C
3 Heat exchanger temp. sensor (TC-sensor) ( - ) 10kΩ at 25°C
4 Louver motor MSBPC20F04 Output (Rated) 1W, 16 poles, DC12V
No. Parts name Type Specifications
L = 10mH, 16A
2 Outdoor fan motor ICF-140-43-4R DC140V, 43W
3 Suction temp. sensor (TS sensor) (Inverter attached) 10kΩ (25°C)
4 Discharge temp. sensor (TD sensor) (Inverter attached) 62kΩ (20°C)
5 Outside air temp. sensor (TO sensor) (Inverter attached) 10kΩ (25°C)
6 Heat exchanger temp. sensor (TE sensor) (Inverter attached) 10kΩ (25°C)
Reactor
1
1
Fan motor
(for indoor)
20A, AC250V
DA131S1B-31FZ
CAM-MD12TCTH-5
STF
3-phases 4-poles 1100W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
Terminal block (5P)7
8
9
10
CH-57 (2 Pcs)