ERROR STOP (1:YES/2:NO) ?
If you select YES (by typing in 1, then pressing
Enter):
When an error occurs, the error status is displayed and execution
of the test program stops and the operation guide is displayed on
the right side of the display screen. If you select NO (by typing in
2, then pressing Enter): When an error occurs, the
error status is displayed then the error counter is incremented by
one and you go to the next test.
8. Type in 1 or 2, then press Enter and the test
program will run. Each subtest is described in section 3.3.
9. When an error occurs during the test program, the following message
will appear: (if you answer YES for ERROR STOP question,)
ERROR STATUS NAME [[ HALT OPERATION ]]
1: Test End
2: Continue
3: Retry
1: Terminates the test program execution and exits to the subtest
menu.
2: Continues the test.
3: Retries the test.
The error code and error status names are described in section
3.15.
~~
DOC:MAINTENANCE MANUAL
MODEL:T5200
MODEL:T5200C
CHAP:3 TESTS AND DIAGNOSTICS
SECT:3.3, SUBTEST NAMES
DOC_ID:3.3 T5200
LANG:ALL
TEXT:
<fig id=MMS\5200\52003_5.TIF>Page 3-5</fig>
3.3 SUBTEST NAMES
Table 3-1 lists the subtest of each test program.
Table 3-1 Subtest names and execution time
ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄ¿
³ No.³Test name ³Subtest No. ³ Subtest item ³Time(s)³
ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ´
³ 1 ³ SYSTEM ³ 01 ³ ROM checksum ³ ³
³ ³ ³ 02 ³ HW status ³ ³
ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ´
³ ³ ³ 01 ³ RAM constant data ³ ³
³ ³ ³ 02 ³ RAM address ³ ³
³ ³ ³ ³ pattern data ³ ³
³ 2 ³ MEMORY ³ 03 ³ RAM refresh ³ ³