press the Enter. The following message will appear.
Data compare error dump (1:no, 2:yes) ?
4. This message is used to select whether to do dump operation or not
when data compare error is detected. Select yes or no and press the
Enter. The following message will appear.
Detail status display (1:no, 2:yes) ?
5. This message is used to select whether to display the detail status
on the screen or not. The detail status are described in section
3.16. Select yes or no and press the Enter.
<fig id=MMS\5200\52003_24.TIF>Page 3-24</fig>
6. During the hard disk test, the message shown below will appear. The
ADDRESS number indicates that the first XXX shows a
cylinder number, the fourth X shows a head number, and the
last XX shows a sector number. The STATUS number
indicates that the first X shows a drive number and the
last XX shows an error status code.
HARD DISK TEST XXXXXXX
SUB-TEST: XX
PASS COUNT: XXXXX ERROR COUNT: XXXXX
WRITE DATA: XX READ DATA: XX
ADDRESS: XXXXXX STATUS: XXX
CONTENTS
Subtest 01 Sequential read
This subtest performs forward reading of contents from
track 0 to Max. and then performs reverse reading of the
contents from Max. track to track 0.
Subtest 02 Address uniqueness
1. Selecting this subtest, the following message will
appear.
Read sequential select?
1: Forward sequential
2: Reverse sequential
3: Random
2. Select one of the above and press the Enter.
This subtest writes the address data that is different
sector by sector at each track, then reads and compares
it to the original data. This test is done for all tracks.
Subtest 03 Random address/data
This subtest writes random data to random addresses
(cylinder, head, sector) and then reads the data out and
compares it to the original data.