7HFKQLFDO,QIRUPDWLRQ
6HUYLFH0DQXDO
0
1
2
3
4
5
6
7
8
9
10
0 20 40 60 80 100 120
Condition
Indoor:DB 27
WB19
Indoor air flow: Turbo
Pipe length:5m
Voltage:230V
Compressor Speed(rps)
0
1
2
3
4
5
0 20 40 60 80 100 120
Compressor Speed(rps)
Cooling
Heating
Cooling
Heating
Current(A)
Current(A)
50
60
70
80
90
100
110
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Condition
Indoor:DB27 WB19
Indoor air flow:
Turbo
Pipe length:5m
Outdoor temp. (°C)
0
20
40
60
80
100
120
Capacity ratio(%)
Outdoor temp. (°C)
09K
12K
09K
12K
-7 -5 0 5 10
Condition
Indoor:DB20
Indoor air flow:
Turbo
Pipe length:5m
6
7
10
8
9
18K
18K
Condition
Indoor:DB 20
Indoor air flow:Turbo
Pipe length:5m
Voltage:230V
2SHUDWLRQ&KDUDFWHULVWLF&XUYH
&DSDFLW\9DULDWLRQ5DWLR$FFRUGLQJWR7HPSHUDWXUH