TABLE 1
NOTE :
When the AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check the
appliance and / or generator for overloading or detect and have repaired as
necessary by TOTAL dealer or service shop.
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
Be sure to ground the generator if
the connected electrical device Is
grounded.
WARNING
TWIST
up to 30A
up to 20A
110-120V~
110-120V~
220-240V~
GFCI (Ground Fault Circuit Interrupter)
Receptacle, duplex
(REC1)
Locking Receptacle (REC4)
Style Ampere Voltage Description
up to 30A
110-120V~
Locking Receptacle (REC3)
up to 32A
220-240V~
BS323 Standard
up to 16A
220-240V~
2P+E European type
up to 16A
220-240V~
BS Standard
VDE
(c) Turn on the switch of the appliance.
(2) STOPPING THE ENGINE
Turn off the switch of load.
Disconnect tool or appliance.
Turn the STOP SWITCH to the position "OFF".
NOTE :
Allow the engine about 3 minutes to cool down at no-load before stopping.