9. TROUBLESHOOTING
When generator engine fails to start after several attempts, or if no electricity is
available at the output socket, check the following chart. If your generator still fails
to start or generate electricity, contact your nearest
further information or corrective procedures.
dealer or service shop for
When Engine Fails to Start :
When No Electricity Is Generated at Receptacle :
Check if choke lever is in its proper
position.
Check if fuel valve is open.
Set the choke lever to "CLOSE"
position.
If closed, open fuel valve.
Check to make sure generator is not
connected to an appliance.
Check spark plug for loose spark plug
cap.
Check spark plug for contamination.
Check if engine switch is in OFF.
If connected, turn off the power switch
on the connected appliance and unplug.
If loose, push spark plug cap back into
place.
Remove spark plug and clean electrode.
Turn engine switch to ON.
Check AC receptacle and DC terminals
for loose connection.
Check to see if engine starting was
attempted with appliances already
connected to generator.
Secure connection if necessary.
Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been
started properly.