Visit WWW.TOTALPOND.COM for information and tips.
EN
6
Cut ring
Adapter before cut Adapter after cut
Step 1. For maximum water
ow, use the largest tubing size.
Trim the tubing adapter using a
hacksaw at the location indicated.
NOTE: If you do not want to use
the largest tubing size, skip to
Step 2.
Step 2. Connect the adapter to
the pump, and connect the tubing
to the outlet of the adapter.
NOTE: Tubing is not included.
Step 3. Place the pump inside the
pumpshield. Pull the drawstring
until the pumpshield is fully closed
around the tubing and power
cord. Tie a knot in the drawstring.
Step 4. Place the pump into the
water and connect to a properly
grounded electrical outlet.
GFCI
Outlet
OPERATION INSTRUCTIONS
1
2
3
4
Max Flow Rate 5100 GPH (at 0 ft.)
Max Pumping Height 23 ft (at 0 GPH)
Recommended
Waterfall Height
18 ft (at 1680 GPH)
Power Consumption 230 watts / 2.5 amps
Cord Length 16 ft.
SPECIFICATIONS
Flow Rates (GPH)
Lift (feet)
23 0
18 1680
17 420 1960
16
660
2260
15 880 2550
14 1090 2770
13 1320 3020
12 1550 3230
11 1780 3410
10 2009 3580
9 2210 3720
8 2360 3870
7 2501 4020
6 2648 4150
5 2770 4320
4 2900 4480
3 3080 4660
2 3310 4830
1 3480 5000
0 3600 5100
52323 52322
Max Flow Rate 3600 GPH (at 0 ft.)
Max Pumping Height 18.3 ft (at 0 GPH)
Recommended
Waterfall Height
12 ft (at 1550 GPH)
Power Consumption 170 watts / 2.5 amps
Cord Length 16 ft.
3,600 GPH Waterfall Pump (#52323)