Conduit E19
(provided on-site)*
(provided on-site)*
Switch box
Back hanger
Controller
Main unit
Upper lid
Stainless steel
Sensor surface
Urinal photoelectric
sensor
Exposure angle and detection area
* For a 300 x 300 mm blank white paper
2015.90GH227
Work Instructions
USWN900 model
* is for 220-240V AC type only
Included Parts
Refer to the following and confirm that no parts are missing.
Install the product properly according to these Work Instructions, to ensure that its functions perform sufficiently.
After installation, provide the customer with a clear explanation of how to use the product.
Auto-cleaning Urinal (USWN900 Series)
Be sure to install an overcurrent breaker and earth leakage
circuit breaker in order to prevent danger
Electric wire: Use a 600V plastic shielded electric wire or cable
(A ø1.6 mm or ø2.0 mm single wire, or 2.0 mm stranded wire)
Insulate and waterproof the power wire connector
Do not insert the power wire connector inside the device
Doing so may cause electric shock, a current leak, or a fire.
Precautions prior to Installation
Do not install in locations of high humidity such as bathrooms
Doing so may cause a malfunction or current leak.
WARNING
Thoroughly discuss the relevant procedures before performing water and
electrical work.
The power wire is to be provided on-site. (220-240V AC type only)
A grounding wire is not needed, so use a two-core power wire. (220-240V AC type only)
Water supply pressure ranges from 0.07 MPa (9 L/min [dynamic]) at minimum to
0.75 MPa at maximum. Use the product within this pressure range.
Be especially careful not to damage the surface of the sensor.
This product is an electrical appliance. Be careful not to spray water on it.
The exposure angle and detection distance of the sensor are as shown in the
diagram. When installing a handrail or the like in front of the urinal, do so in a way
that does not obstruct the detection areas (both the stable detection area and
unstable detection area) of the photoelectric sensor. Avoid installing the product in a
location that is highly reflective (such as in a location where a stainless steel wall is in
front of the photoelectric sensor), as this could cause malfunctions.
The product may not function in environments exposed to strong sunlight.
Inverters or other devices that use infrared light could cause malfunctions.
A water supply inspection has been conducted prior to packaging. There may be
some water remaining inside the product, but this is normal.
Parts Names
Use prohibited near water
REQUIRED
Always carry out construction work with at least two people
Otherwise, the installer may injure his or her lower back, or drop the porcelain and damage it.
After construction, be sure to give the product a test run and
check that there are no water leaks in any part.
Not installing the product properly may cause water leaks that could result
in flooding damage to property, such as household belongings.
Safety Precautions (be sure to read to ensure safety)
WARNING
CAUTION
People other than repair technicians should never disassemble,
repair, or alter the product.
Doing so may cause a malfunction, electric shock, or injury.
Do not install in locations of high humidity such as bathrooms
Doing so may cause a malfunction or current leak.
Read these “Safety Precautions” prior to construction, and install the product correctly. These
Instructions include a variety of safety indications. These are provided so that the product can
be used safely, to prevent harm to customers or others, and to prevent damage to property.
These indications and their meanings are as follows:
CAUTION
Ignoring the text accompanying this indication and handling the
product incorrectly could result in serious injury or property damage.
WARNING
Ignoring the text accompanying this indication and handling the
product incorrectly could result in death or serious injury.
Indication
Meaning
indicates a required step in the use of this product.
The symbol to the left indicates the action is “REQUIRED.”
indicates a prohibited use of the product.
The symbol to the left indicates that “use is prohibited in bathtubs and shower stalls.”
REQUIRED
Disassembly prohibited
Use prohibited near water
The discharge pipe above the fishedwalls surface
should be limited between 25
~
30 mm.
Shutoff valve
Photoelectric
sensor
Decorative bolt
Drain cover
Detection distance exposure
angle 650mm
Pointing down 15°
Unstable detection area
Stable detection area
ø160
15°
ø300
500
Detection
distance
*
“Property damage” refers to damage extending to the home/household property and domestic animals/pets.
Types of safety precautions that must be followed are classified using the two following symbols for explanatory purposes.
Drainage flange
(one)
Upper lid Drain cover
* Sterilization type with sponge (shaded area)
Water supply fixture
Others
Quick fastener
(1)
Shutoff valve
(1)
Work Instructions
(1; this document)
Instruction
Manual
(1)
Hand this over
to the customer
Back hangers
(2)
Wood screw set
(6 wood screws,
2 washers)
Draining Flange
Alkaline batteries
(2)
Alkaline battery
type only

Battery box (1)
Alkaline battery
type only
Washer [large]
(1) (for urinal)
Tapping
screws (4)
Work
Instructions
(1)
Bolt
(1)
Drainage
flange unit
(1)
M8 nuts
(2)
Washer
[small] (1)
P seal
(1)
Urinal

Other manuals for Toto USWN900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toto USWN900 Series and is the answer not in the manual?

Toto USWN900 Series Specifications

General IconGeneral
ModelUSWN900 Series
TypeOne-Piece Toilet
Bowl ShapeElongated
Flush SystemTornado Flush
Heated SeatYes
Bidet FunctionYes
Remote ControlYes
Night LightYes
MaterialCeramic
ADA CompliantYes
Rough-In Size12 inches
Seat Height16.5 inches
ColorCotton White
CeFIONtect GlazeYes
Siphon JetYes
Water Consumption0.8 GPF / 1.28 GPF (Dual Flush)