7
7
NOTE:
When fire the plastic strip nail to the common concrete, should pay attention to control the nail fire place
with the concrete marginal range and the nail between the nail range, if the distance undersize, the
concrete will easy to crack to injure yourself or someone around you.
Suggest the nail fire place with the concrete marginal range no less than 50mm, nail between the nail ranges
no less than 60mm.
WARNING
Be sure to use only the genuine TOUA nails as the above sizes. The use of any other nails can result in
tool malfunction or nail breakdown, leading to serious injuries.
Only nails shown in the above table can be driven with this Nailer.
3. Fuel cell
Fuel Cell Sold Separately, Specification as below:
1
Φ31.5mm x 165mm Pressure 16 18 bar,
Using temperature range : 23
℉(-5)~120℉(50
Model No: FC165-1-1
2
Φ31.5mm x 165mm Pressure 10.8 11.8 bar,
Using temperature range : 23
℉(-5)~120℉(50
Model No: FC165-2-1
4
Charger
Input power source AC110
240V / 50 60Hz/0.35A
Charge time About 2hrs
Charging voltage DC 6V
Charging current DC 0.7A
Charger Weight 0.15Kg
Adapter Weight 0.085Kg