EasyManua.ls Logo

TP-Link TL-R480T+ - Page 17

TP-Link TL-R480T+
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Load Balance Broadband Router
Grounding T e rminal Equipotential Bonding Cable
Grounding Bar Ground Cable
Equipotential BondingFigure 3-3
When equipotential bonding, please note that the cable should be copper wrapped
Kelly with its area being 6mm
2
at least. The shorter cable the better, and use a
grounding bar to establish an equipotential bonding point.
Note: The equipotential bonding cable is not provided with our product. If needed,
please self purchase it.

Power lightning arrester and signal lightning arrester are used for lighting protection.
Power lightning arrester is used for limiting the voltage surge due to a lightning. If an
outdoor AC power cord should be directly connected to the device, please use a power
lightning arrester.
Note: Power lightning arrester is not provided with our product. If needed, please self
purchase it.
Lightning Protection

Other manuals for TP-Link TL-R480T+