System contains refrigerant under high pressure. Recover before opening.
Product exposes to lead, known to cause cancer and birth defects.
Coils designed for heat pump/cooling outdoor sections using R-410A.
Coil must be installed downstream of the furnace outlet air.
Indoor unit must provide required airflow for approved combinations.
Gasket kit prevents water formation on drain pan in humid applications.
Optional removal of coil components to maximize airflow efficiency.
Apply gasket material and secure coil case to furnace for air leaks.
Optional removal of coil components to maximize airflow efficiency.
Optional kit to prevent water formation on drain pan in humid conditions.
Secure coil case to furnace plenum and furnace to coil case.
Optional removal of coil components to maximize airflow efficiency.
Furnace top flange meets coil top flange; seal gaps between units.
Optional removal of coil components to maximize airflow efficiency.
Coil rotated so apex is away from furnace; auxiliary drain pan is lower.
Use brackets for alignment and splash guard for drain pan.
Use standoffs and screws for alignment, not for support in horizontal position.
Lists maximum airflow settings (CFM) for Upflow, Horizontal Left, Downflow, and Horizontal Right.
TXV setting may run high superheat (15-25°F) by design.
Determine run, consider bends, route tubing, and secure before connections.
Protect TXV bulb during brazing to maintain performance.
Shield painted areas, use nitrogen flow, good technique, minimize sharp bends.
Remove panels, clean inside and outside of coil with brush and vacuum.
Pressurize with nitrogen, check brazed connections with soap bubbles, repair leaks.
Clear drain hole, insulate primary line, connect secondary line without a trap.
Diagnoses TXV issues based on superheat, subcooling, and airflow.