Table of Contents
General ............................................................................... 1
Application Information ................................................ 1
Recommendation ............................................................. 2
Furnace in Upflow Position .......................................... 2
Furnace in Downflow Position ..................................... 2
Furnace in Horizontal Right Position ........................ 3
Furnace in Horizontal Left Position ........................... 4
Maximum Airflow Setting, CFM ................................... 5
Installing / Brazing Refrigerant Lines ....................... 5
Leak Check........................................................................ 6
Condensate Drain Piping .............................................. 6
Cleaning the Coil ............................................................. 6
Outline Drawings ............................................................ 7
Troubleshooting Indoor TXV / Cooling Mode ......... 10
Installer’s Guide
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
WARNING
!
WARNING (Medium/high pressure)
Contains Refrigerant!
System contains oil and refrigerant under high pressure.
Recover refrigerant to relieve pressure before opening the
system. See unit nameplate for refrigerant type. Do not
use non-approved refrigerants, refrigerant substitutes, or
refrigerant additives.
Failure to follow proper procedures or the use of non-
approved refrigerants, substitutes, or refrigerant additives
could result in death, serious injury, or equipment damage.
A341869P33
IMPORTANT: Review your installation requirements. Check
the table on the outline drawings and note all dimensions
for your coil before beginning the installation.
Figure 1
18-AD35D1-2D-EN
Cased Aluminum "Convertible" Coils
Models:
4TXCA002DS3HCA
4TXCA032DS3HCA
4TXCB003DS3HCA
4TXCB004DS3HCA
4TXCB006DS3HCA
4TXCC005DS3HCA
4TXCC007DS3HCA
4TXCD008DS3HCA
4TXCC009DS3HCA
4TXCD010DS3HCA
NOTE:
OPTIONAL DOWNFLOW GASKET INSTALLATION: For
unusually humid applications that expect prolonged
operation above 70% RH, it is recommended to use the
BAYGSKT001A0 gasket kit to prevent water from forming
on the bottom of the drain pan and dripping into the sup-
ply ductwork.
WARNING
!
This product can expose you to chemicals including lead, which
are known to the State of California to case cancer and birth defects
or other reproductive harm. For more information go to www.
P65Warnings.ca.gov
A. GENERAL
These coils are designed for use in combination with a heat pump
or cooling outdoor section using R-410A REFRIGERANT.
The 4TXC equipment has been evaluated in accordance with
the Code of Federal Regulations, Chapter XX, Part 3280 or the
equivalent. “Suitable for Mobile Home use” The height of the
Furnace, Coil and discharge duct work must be 7 ft. or less.
Inspect the coil for shipping damage. Notify the transporta-
tion company immediately if the coil is damaged.
B. APPLICATION INFORMATION
1. FURNACE AND COIL
The coil MUST BE installed downstream (in the outlet air)
of the furnace.
2. INDOOR UNIT AIRFLOW
Indoor unit must provide the required airflow for the heat
pump or cooling combinations approved for these coils.
Question and Answer IconNeed help?

Do you have a question about the Trane 4TXCC009DS3HCA and is the answer not in the manual?

Trane 4TXCC009DS3HCA Specifications

General IconGeneral
BrandTrane
Model4TXCC009DS3HCA
CategoryFurnace Accessories
LanguageEnglish

Summary

General and Application Information

General Coil Application and Requirements

Specifies R-410A refrigerant use, compliance with codes, and inspection for shipping damage.

Application Information: Furnace and Airflow

Details coil placement downstream of furnace and required indoor unit airflow for system operation.

Furnace Installation Procedures

Upflow Furnace Installation Steps

Covers coil conversion, gasket application, and securing the coil to an upflow furnace.

Downflow Furnace Installation Steps

Covers coil conversion, optional gasket, and securing the coil to a downflow furnace.

Horizontal Right Furnace Installation

Horizontal Right Coil Conversion Options

Optional removal of coil components for improved airflow efficiency.

Connecting Coil to Furnace (Horizontal Right)

Instructions on connecting furnace and coil using screws, sealing gaps, and ensuring flange alignment.

Horizontal Left Furnace Installation

Horizontal Left Coil Conversion Options

Optional removal of coil components for improved airflow efficiency.

Horizontal Left Installation Steps

Details on coil rotation, bracket use for furnace/coil connection, and splash guard installation.

Airflow Settings and Refrigerant Line Installation

Maximum Airflow Setting Charts

Tables provide maximum airflow (CFM) for various models and installation orientations.

Refrigerant Line Brazing and Installation

Comprehensive guide for routing, brazing, connecting lines, protecting TXV, and insulating.

System Checks and Maintenance

Leak Check and System Charging Procedure

Steps for leak checking with nitrogen, evacuation, and system charging.

Condensate Drain Piping Installation

Instructions on clearing drain, insulating primary line, and connecting secondary drain.

Coil Cleaning Instructions

Guide on cleaning the indoor coil after panel removal using brushes and vacuum.

Troubleshooting Indoor TXV and Cooling

Diagnosing Subcooling and Superheat

Steps to diagnose system performance issues by checking subcooling and superheat.

Verifying Airflow and TXV Operation

Check airflow rates and test TXV bulb response to ambient temperature changes.

Inlet Screen Inspection and TXV Replacement

Inspect the TXV inlet screen for blockages and replace TXV if necessary.