Electrical Wiring
Warning
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY
ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE
VOLTAGE CONNECTIONS.
Precautions for Electrical wiring
Electrical wiring work should be conducted only by authorized personnel .
Do not connect more than three wires to the terminal block . Always use round type
crimped terminal lugs with insulated grip on the ends of the wires .
Use copper conductor only .
Item
Model
Phase
Circuit breaker
Power source
wire size
(minimum)
(mm 2 )
Earth leakage breaker
Switch
breaker (A)
Overcurrent
protector rated
capacity (A)
Switch
breaker (A)
Leak
current(mA)
4MXD6536G1000AA
4MXD6548G1000AA
1 40 30 6.0 40 30