Use only copper wires .
A main switch or other means for disconnection, having a contact separation in all poles, must be
incorporated in the fixed wiring in accordance with applicable legislation . Do not turn on the main switch until
all the wiring is completed .
Make sure to connect power supply cables in normal phase .
Never squeeze bundled cables into a unit .
Fix cables so that cables do not make contact with the pipes (especially on high pressure side) .
Secure the electrical wiring with cable ties as shown in the figure in 10 .2 .
Make sure no external pressure is applied to the terminal connectors .
When installing the earth leakage circuit breaker make sure that it is compatible with the inverter (resistant to
high frequency electrical noise ) to avoid unnecessary opening of the earth leakage circuit breaker .
As this unit is equipped with an inverter, installing a phase advancing capacitor not only will deteriorate power
factor improvement effect, but also may cause capacitor abnormal heating accident due to high-frequency waves
. Therefore, never install a phase advancing capacitor.
Caution
Be sure to install the required fuses or circuit breakers.
Connecting power supply and inter-unit wiring
Connect and fix the power supply cable, indoor-outdoor connection cable as following:
116
Y/G
1
3
2
2
1
Outdoor unit
Power supply:
1PH,220-
240V~, 50/60Hz
L N
indoor unit
1 2 3
Power supply:
1PH,220-
240V~, 50/60Hz
Outdoor unit
terminal blocks
Indoor unit
terminal blocks