Caution
ln installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The
refrigerant gas will generate poisonous gas upon contacting fire.
After installation, please verify that there is no refrigerant leakage. The leaked refrigerant gas will
produce poisonous gas when meeting fire source such as heater and furnace etc.
Pipe size (unit:mm)
Model Gas side Liquid side
4MXD6512G1000AA Ø9.52 Ø6.35
4MXD6518G1000AA Ø12.7 Ø6.35
4MXD6524G1000AA Ø15.88 Ø9.52
4MXD6536G1000AA 4MXD6548G1000AA 4MXD6560G1000AA Ø19.05 Ø9.52
9 2