SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
April 2020
8888--AA880011XX000011--11CC--EENN
Upflow/Downflow/Horizontal Left/Right
Gas-Fired, Single Stage Induced Draft Furnaces with High
Efficiency Motor
UUppffllooww,, DDoowwnnffllooww,, HHoorriizzoonnttaall RRiigghhtt//LLeefftt
Single Stage
A801X026AM2SAC
A801X040AM3SAC
A801X040BM2SAC
A801X060BM3SAC
A801X060BM4SAC
A801X080BM4SAC
A801X080CM5SAC
A801X100CM5SAC
A801X120DM5SAC
NNoottee:: This installer’s Guide is used for multiple furnace families. Models
may have a “T” in the 12th digit designating they meet California less
than 40 ng/J (NOx) emissions requirements.
NNoottee:: Graphics in this document are for
representation only. Actual model may
differ in appearance.
Installer’s Guide

Other manuals for Trane A801X060BM3SAC

Question and Answer IconNeed help?

Do you have a question about the Trane A801X060BM3SAC and is the answer not in the manual?

Trane A801X060BM3SAC Specifications

General IconGeneral
BrandTrane
ModelA801X060BM3SAC
CategoryFurnace
LanguageEnglish

Summary

Furnace Installation Guidelines

Safety Practices and Precautions

Essential safety practices and precautions for installation, servicing, and operation.

Furnace General Installation

Gas Piping

Detailed instructions and diagrams for gas piping connections.

Combustion and Input Check

Procedure for checking gas flow rate and input for proper furnace operation.

Gas Valve Adjustment

Steps for adjusting the gas valve and manifold pressure for correct operation.

General Venting

Electrical Connections

General Start-up and Adjustment

Control and Safety Switch Adjustment

Procedures for checking and adjusting limit switches and other controls.

Integrated Furnace Control Menu

Fault Code Recovery

Procedures for viewing, clearing, and resetting fault codes on the IFC.

Sequence of Operation