EasyManua.ls Logo

Trane A801X060BM3SAC - Page 45

Trane A801X060BM3SAC
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88-A801X001-1C-EN
45
Table 10. Venting Options for Horizontal Left Applications
Refer to the illustrations below to find the approved venting options for horizontal left furnace.
Important: The exhaust must be vented to the outdoors.
Horizontal Left Orientation or Installation
Vented out top.
Vented through left side.
Table 11. Venting Options for Horizontal Right Applications
Refer to the illustrations below to find the approved venting options for horizontal right furnace.
Important: The exhaust must be vented to the outdoors.
Horizontal Right Orientation or Installation
Vented out top.
Vented through right side.
FFuurrnnaaccee CCoommbbuussttiioonn AAiirr EExxhhaauusstt OOppttiioonnss