EasyManua.ls Logo

Trane BAYEVAC04BK1B - Page 11

Trane BAYEVAC04BK1B
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 11
INSTALLER'S GUIDE
HAZARDOU
S VOL
T
AGE!
DI
S
CO
NNE
C
T
A
LL
E
L
E
CT
RICA
L
P
O
W
E
R
I
NCLUD
I
N
G
RE
MO
T
E
DI
S
C
ONNE
C
T
S
BEF
OR
E
SERV
IC
ING.
Fa
il
ure t
o d
isc
onnect
pow
e
r
be
fo
r
e
ser
v
i
c
ing can
c
au
se
s
e
v
e
re
pe
rs
ona
l
i
n
ju
r
y or death
.
WARNING
U
SE CO
PPE
R
CO
NDUC
T
O
R
S ONL
Y
!
UN
I
T
T
E
RMI
N
A
L
S A
RE
NOT
DES
I
G
N
ED
T
O A
CC
EPT
O
T
HE
R
T
YPES
OF
CONDUC
T
OR
S
.
F
a
ilur
e
t
o
do so
m
a
y cau
s
e dam
age
to t
he equi
p
m
ent
.
CA
UT
ION
LEGE
ND
24
V
L
IN
E
V
F
A
C
T
ORY
W
IRE
NU
T
OR
T
E
RMINA
L
CHASSI
S
GRO
UND
C
O
NNE
CTOR
24
V
L
IN
E
V
F
I
E
L
D
W
I
RI
NG
WIRING
P
D-A
PD
-
B
W
1
W2
W3
WJ
C
TC
O
C
T
CO
B
K
B
K
B
K
B
K
B
K
B
K
B
K
B
K
WH
WH
WH
WH
208/240 VOLT 60 HZ
1 PH POWER SUPPLY
PER LOCAL CODE
E
LECTRIC
HEAT
CO
N
TROL
LO
W V
OLTA
GE
WIRIN
G
T
1
1
T
1
2
T1 T2 T3 T
4
T
5 T
6
T7 T8 T9T
1
0
(EHC)
IN AIR H
A
NDL
ER
GR GR
BK
RD
3 1
HI
GH
V
OL
T
A
G
E
W
I
RING I
N
A
I
R
HA
ND
LE
R
M
O
DEL
BAYEAB
C20
BK1
HEA
T
E
R
RA
TI
NG
S
K
W
/A
M
PS
A
T
A
B
240 V
O
L
T
S
208 V
O
L
TS
4.80
/
2
0
4
.
80
/
2
0
3.6
/17.
3
3
.
6
/17
.
3
C
4
.
80
/
2
0
3
.
6
/
17
.3
CI
RCUI
T
I CIRCUI
T II
9
.
60/
4
0
9
.
60
/
4
0
7
.
20/
34
.
6
7
.
20/
34.
6
D
4
.
80
/
2
0
3
.
6
/
17
.
3
TOT
A
L
HEA
TE
R RA
T
I
N
GS
K
W
/
A
M
PS
RD
R
D
RD
RD
RD
R
D
(
FE
MA
LE
TE
RMINA
L
S
)
(
M
A
L
E T
E
RM
I
N
A
LS)
P
OL.PLUG F
E
MA
L
E
H
OUS
I
N
G
P
OL
.
PL
U
G MA
LE
HOU
S
ING
P
D
POWE
R
DI
S
C
ONNE
C
T
H
T
R H
EAT
E
R
C
T
CO C
Y
CL
I
NG
TE
M
PE
R
A
T
UR
E LI
M
I
T
S
W
I
T
CH
C
O
LOR
O
F
W
IR
E
C
O
LOR O
F
M
AR
KE
R
BK
B
L
A
C
K
RD
R
E
D
O
R
O
R
A
N
G
E
B
R
B
R
O
W
N
Y
L
YE
LLO
W
P
R
P
UR
PLE
B
L
B
LU
E
W
H
W
HITE
G
R
G
R
EE
N
PK
P
IN
K
F
L
F
U
S
I
B
L
E
L
INK
P
L
PLUG
BK
B
K
B
K
B
K
B
K
B
K
BK
B
K
B
K
BK
RD
R
D
RD
R
D
BL
BL
BL
B
L
BL
B
L
BL
B
L
P
RINT
E
D
F
ROM
D803269
P03
P
L
-
1
P
L
-
2
PL-
3
G
L
G
ROUND
LUG
GL
H
TR-
A
H
T
R-
B
HT
R-
C
HT
R
-D
N
T
C
O
N
ON
C
Y
CL
I
NG
TEMPER
A
TURE
LI
M
I
T
S
WI
T
C
H
24VA
C
12V
DC
T
E
MPER
A
T
URE
L
I
M
IT
S
W
I
T
CH
NT
CO
NT
C
O
C
1
C
1
C
1
C
1
C
2
C
2
C
2
C
2
H
1
H1
H
2 H
2
H
3
H
3
H
4
H
4
T
1 T
2
T3
T
4
T5
T
6
T
7
T
8
STEP 13 - Replace Heater compartment panel on air
handler.
STEP 12 - Remove breaker cover.
1. Remove 5/16 hex screw on back of breaker cover.
2. Remove and discard the two piece breaker cover from
the heater compartment panel.
Note: Breaker models only.
STEP 14 - On the unit nameplate, check off the heater
that is being installed or apply the new secondary
nameplate label within the heater data table on the air
handler nameplate as shown.

Related product manuals