MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX
AIR HANDLER MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX
MODEL
NUMBER
1405 000
BRK
PDC
4.80kw
1408 000
BRK
PDC
7.68kw
1410 000
BRK
PDC
3410 000
9.60kw
1415 BRK
15.36kw
3415 000
15.36kw
1419 BRK
19.20kw
1425 BRK
24.96kw
NUMBER OF HEATER RACKS1223345
TWG018A
L / L L / M L / H--------
2TGB3F18 / 2TGB3F25 / TWG025A
L / L L / M L / M L / H L / H -- --
2TGB3F30 / TWG030A
L / L L / L L / L L / M L / M -- --
2TGB3F36 / TWG036/037A
L / L L / L L / L L / M L / M -- --
2TBG3F42 / TWG042A
L / L L / L L / L L / H L / H -- --
TWG048A
L / L L / L L / L L / H L / H L / M --
2TGB3F48 / TWG060A
L / L L / L L / L L / L L / L L / M L / H
TEC / TWE018C
L / L L / M L / M--------
TEC / TWE024C
L / L L / L L / L L / M L / M -- --
TEC / TWE030C
L / L L / L L / L L / M L / M -- --
TEC / TWE036C
L / L L / L L / L L / L L /L
PS
--
TEC / TWEO42C
L / L L / L L / L L / H L /H
AS
--
TWE048C
L / L L / L L / L L / L L / L L / H L / H
TEC3F48
L / L L / L L / L L / L L / L L / H
TWE060C/D
AS
L / L L / L L / L L / L L / H L / H
TEC3F60
L / L L / L L / L L / L L / H
4TEP/TWE018P
L / L L / M L / M--------
4TEP/TWE024P
L / L L / L L / L L / M L / M -- --
4TEP/TWE030P
L / L L / L L / L L / M L / M -- --
4TEP/TWE036P
L / L L / L L / L L / H L / H L / H --
4TEP/TWEO42P
L / L L / L L / L
PS PS
L / H --
4TEP/TWE048P
L / L L / L L / L
PS PS
L / H L / H
TWE060P
L / L L / L L / L
PS PS
L / H L / H
4TEP/TWE063P
L / L L / L L / L
PS PS
L / H L / H
TEE3D/TEE3F/TWE031E
700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 --
TEE3D/TEE3F/TWE037E
600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 --
TEE3D/TEE3F/TWE040E
600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400
TEE3D/TEE3F/TWE049E
700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600
TEE3D/TEE3F/TWE065E
900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800
TWE062E*
900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800
TEE3C31*
1000/1130
PS/AS
1130/1350 1130/1350 1130/1350 1130/1350 --
TEE3C37*
600/900 900/1100 1100/1450 1100/1450 1100/1450 1100/1450 --
TEE3C40*
PS/AS
600/900 900/1100 1100/1400 1100/1400 1100/1400 1100/1400
TEE3C49*
800/1100 800/1100 800/1400 1100/1700 1100/1700 1400/1700 1400/1700
TEE3C65*
900/1200 900/1200 1200/1500
PS/AS PS/AS
1200/1500 1500/1800
COOLING / HEATPUMP AIRFLOW
AS = Heater application is affected based on whether the outdoor unit is a heat pump or cooling unit.
PS = Minimum speed tap varies based on air handler installation position.
SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR AS/PS NOTES
000 = pigtails, BRK = contains circuit breakers, PDC = contains pull disconnect
* These unts require BAYHTR*******C series heaters