15.6 Temperature sensor resistance table
15.7 Electrical data table
Temperature
°F
Resistance kΩ Temperature
°F
Resistance kΩ Temperature
°F
Resistance kΩ Temperature
°F
Resistance kΩ
-4 106.73 37 29.87 78 10.00 119 3.69
-3 103.25 38 29.22 79 9.50 120 3.61
-2 99.89 39 28.19 80 9.26 121 3.53
-1 96.65 40 27.39 81 9.03 122 3.45
0 93.53 41 26.61 82 8.81 123 3.38
1 90.53 42 25.85 83 8.59 124 3.30
2 87.62 43 25.12 84 8.38 125 3.23
3 84.83 44 24.42 85 8.17 126 3.16
4 82.13 45 23.73 86 7.97 127 3.10
5 79.52 46 23.07 87 7.78 128 3.03
6 77.01 47 22.42 88 7.59 129 2.96
7 74.58 48 21.80 89 7.40 130 2.90
8 72.24 49 21.20 90 7.22 131 2.84
9 69.98 50 20.61 91 7.05 132 2.78
10 67.80 51 20.04 92 6.88 133 2.72
11 65.69 52 19.49 93 6.72 134 2.67
12 63.65 53 18.96 94 6.56 135 2.61
13 61.68 54 18.44 95 6.40 136 2.56
14 59.78 55 17.94 96 6.25 137 2.50
15 57.95 56 17.45 97 6.10 138 2.45
16 56.17 57 16.98 98 5.96 139 2.40
17 54.46 58 16.52 99 5.82 140 2.35
18 52.80 59 16.08 100 5.68 141 2.30
19 51.20 60 15.65 101 5.55 142 2.25
20 49.65 61 15.23 102 5.42 143 2.21
21 48.16 62 14.83 103 5.30 144 2.16
22 46.71 63 14.43 104 5.18 145 2.12
23 45.31 6
4 14.05 105 5.06 146 2.08
24 43.95 65 13.68 106 4.94 147 2.03
25 42.64 66 13.32 107 4.83 148 1.99
26 41.38 67 12.97 108 4.72 149 1.95
27 40.15 68 12.64 109 4.61 150 1.91
28 38.97 69 12.31 110 4.51 151 1.88
29 37.82 70 11.99 111 4.41 152 1.84
30 36.71 71 11.68 112 4.31 153 1.80
31 35.64 72 11.38 113 4.21 154 1.77
32 34.60 73 11.09 114 4.12 155 1.73
33 33.59 74 10.80 115 4.03 156 1.70
34 32.61 75 10.53 116 3.94 157 1.66
35 31.67 76 10.00 117 3.85 158 1.63
36 30.76 77 10.00 118 3.77 159 1.60
18 24 30 36 42 48 60 18 24 30 36 42 48 60
Minimum circuit ampacity(A) 10.4 13.4 14.7 19.4 21.6 24.6 29.6 10.4 13.4 16.5 19.4 21.6 24.6 28.8
Maximum circuit protecetor(A) 15 20 25 30 35 40 50 15 20 25 30 35 40 45
AC HP
Model
Table 9
Table 10
Compressor operates and T3 < 32°F for a period of 30
minutes.
T3 < 28.4°F and compressor operates for the first time after
connected to the power source.
When T3 < 28.4°F and the system is on standby for two hours
continuously.
Compressor operates and T3 < 32 °F for a period of 60
minutes.
T3 < 28.4 °F and compressor operates for the first time after
connected to the power source.
When T3 < 28.4 °F and the system is on standby for two hours.