06691$(1
&RQQHFWLRQ3LSH
2MWW0509G1 2MWW0512G1 2MWW0512G9 2MWW0518G1 2MWW0524G1 2MWW0530G1
2TWK0509G1 2TWK0512G1 2TWK0512G9 2TWK0518G1 2TWK0524G1 2TWK0530G1
R-22 / 1.02 R-22 / 1.1 R-22 / 1.1 R-22 / 1.5 R-22 / 1.4 R-22 / 2.6
7.5 7.5 7.5 7.5 7.5 7.5
15 25 20 30 50 50
Outer
Liquid Pipe
(mm)
ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”)
Diameter
Gas Pipe
(mm)
ĭ9.52(3/8”) ĭ
12(1/2”) ĭ12(1/2”) ĭ12(1/2”) ĭ16(5/8”) ĭ16(5/8”)
Max Height (m) 10 10 10 10 10 10
Distance Length (m) 15 20 20 25 25 30
2MCW0509G1 2MCW0512G1 2MCW0512G9 2MCW0518G1 2MCW0524G1 2MCW0530G1
2TTK0509G1 2TTK0512G1 2TTK0512G9 2TTK0518G1 2TTK0524G1 2TTK0530G1
R-22 / 0.77 R-22 / 1.05 R-22 / 1 R-22 / 1.45 R-22 / 1.3 R-22 / 2.5
7.5 7.5 7.5 7.5 7.5 7.5
15 25
20 30 50 50
Outer
Liquid Pipe
(mm)
ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”) ĭ6(1/4”)
Diameter
Gas Pipe
(mm)
ĭ9.52(3/8”) ĭ12(1/2”) ĭ12(1/2”) ĭ12(1/2”) ĭ16(5/8”) ĭ16(5/8”)
Max Height (m) 10 10 10 10 10 10
Distance Length (m) 15 20 20 25 25 30
Standard Eff
60Hz(C/O)
Refrigerant Charge
(kg)
Connection Pipe
Length (m)
Gas additional
charge(g/m)
Connection Pipe
Standard Eff
60Hz(H/P)
Gas additional
charge(g/m)
Length (m)
Refrigerant Charge
(kg)