Model Number | TAM7A0A24H21SB |
---|---|
Product Category | Air Handlers |
Refrigerant | R-410A |
Energy Efficiency Ratio (EER) | Up to 12.5 |
Voltage | 208/230V |
Motor Type | Variable Speed |
Phase | 1 |
Maximum Overcurrent Protection | 15A |
Shipping Weight | 150 lbs |
Nominal Capacity | 2 Tons |
Cooling Capacity | 24000 BTU |
Heating Capacity | 24000 BTU |
Width | 21 inches |
Details allowed screw locations and cabinet penetrations for installation and wiring.
Step-by-step instructions for brazing refrigerant lines, including preparing connections and using heat.
States that high voltage power must match the equipment nameplate and comply with codes.
Details steps for routing high voltage wiring, selecting conduit entry points, and connecting conduit.
Lists system charge adjustments (subcooling) for various SEER ratings and matched indoor/outdoor units.
Provides sequential steps for starting up the system, including thermostat settings and power application.
Explains unit features, analog inputs, and the importance of dip switch settings for operation.
Details the sequence of operation for a single-stage heat pump in heating mode.
Explains the operational sequence for a two-stage heat pump in heating mode.
Details the sequence of operation for a single-stage outdoor unit in cooling mode.
Describes the sequence of operation for a two-stage outdoor unit in cooling mode.
Explains unit operation with electric heat, including EHC and blower control.