SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
September 2021
VVAAVV--SSVVXX0088RR--EENN
Installation, Operation, and Maintenance
VariTrane Variable Air Volume
(VAV) Terminal Air Units
Shutoff, Fan Powered, and CoolSense™
Sensible Cooling
SSiinnggllee--DDuucctt:: VCCF, VCEF, VCWF
DDuuaall--DDuucctt:: VDDF
FFaann--PPoowweerreedd:: VPCF, VPEF, VPWF, VSCF, VSEF, VSWF
FFaann--PPoowweerreedd LLooww HHeeiigghhtt:: LPCF, LPEF, LPWF, LSCF, LSEF, LSWF
CChhiilllleedd WWaatteerr SSeennssiibbllee CCoooolliinngg TTeerrmmiinnaall UUnniittss:: LDCF, LDEF, LDWF
Question and Answer IconNeed help?

Do you have a question about the Trane VariTrane VPWF and is the answer not in the manual?

Trane VariTrane VPWF Specifications

General IconGeneral
ModelVPWF
Drive TypeDirect drive
Motor TypeECM (Electronically Commutated Motor)
Sound PerformanceLow sound levels
ApplicationsCommercial buildings
ConstructionHeavy-gauge galvanized steel
CertificationsAHRI certified, UL listed
Impeller TypeForward-curved or backward-inclined

Summary

Introduction

Proper Field Wiring and Grounding Required

Emphasizes the necessity of qualified personnel for safe and compliant electrical wiring and grounding.

Personal Protective Equipment (PPE) Required

Details the mandatory use of PPE to protect against electrical, mechanical, and chemical hazards.

Follow EHS Policies

Stresses adherence to Environmental, Health, and Safety policies for all personnel.

Receiving and Handling

Instructs on the proper procedures for inspecting and handling delivered equipment.

Unit Information

Single Duct VAV Units

Describes the basic components and function of single duct VAV units.

Dual-Duct VAV Units

Explains the design and operation of dual-duct VAV units.

Unit Installation

Hazardous Voltage w/Capacitors!

Warns about the dangers of electrical voltage and capacitors during servicing.

Proper Structural Support Required!

Emphasizes the need for adequate structural support to prevent unit failure and injury.

Unit Setup

Adjusting the SCR Motor Speed Control

Explains how to adjust fan speed using the SCR controller's external knob or internal potentiometer.

Wiring Diagrams

Wiring - Electric Heater Control Box

Presents wiring diagrams for electric heater control boxes in single-duct units.

Control Box Wiring

Illustrates wiring diagrams for control boxes in fan-powered units.

Maintenance

Fan Motor Replacement

Provides guidance on accessing and replacing fan motors in different unit configurations.