Dryspell Series Instruction Manual
INSTALLATION AND MAINTENANCE
Safety
Dryspell dryers are intended for the drying of compressed air. Under no circumstance
should they be used to dry other gases.
The desiccants used are not toxic. However, they may cause respiratory problems if they are
inhaled in dust form. The use of a dust mask is sufficient to protect personnel.
Installation Site and Connections
Install the dryer in a closed clean, dry room protected from freezing. Access to the
room should be restricted to personnel qualified in maintenance and operation. The
room must be adequately ventilated. The dryer must not be directly exposed to
sources of heat. The temperature of the room must not exceed 43°C/109°F.
Make sure that the dryer is not near any equipment which does not comply with the
electromagnetic compatibility directives and which may degrade dryer operation. There
must be a minimum distance of 3 feet between the dryer and any other equipment
which uses electricity.
Ensure that the dryer is installed in the vertical position.
Dryer should be secured by bolting it down.