MS-1650B
DIGITAL MEMORY OSCILLOSCOPE
INSTRUCTION MANUAL
TRIO
Question and Answer IconNeed help?

Do you have a question about the Trio MS-1650B and is the answer not in the manual?

Trio MS-1650B Specifications

General IconGeneral
ModelMS-1650B
CategoryTest Equipment
TypeSignal Generator
Output Impedance50 Ohms
ModulationAM, FM
Power SupplyAC 50/60 Hz
Weight5 kg

Summary

FEATURES

Digital Memory and Waveform Storage

Stores and displays transient, repetitive, and instantaneous waveforms using digital memory.

Advanced Operational Functions

Features DELAY function, automatic free-run, and SMOOTHER switch for enhanced usability.

Connectivity and Multi-Trace Capability

Supports MU-1651 for multi-trace display and X-Y scope operation.

TECHNICAL SPECIFICATIONS

Vertical and Horizontal Axis Parameters

Details sensitivity, input impedance, and frequency response for both axes.

Memory Unit and Sweep/Sync Circuits

Covers memory capacity, write/readout speeds, sweep time, and sync input specifications.

CRT and A/D Converter Details

Information on Cathode Ray Tube, operating modes, and A/D converter resolution.

CONTROL PANEL OVERVIEW

Front Panel Controls

Adjustments for power, intensity, focus, trace, sensitivity, and position.

Rear Panel Connectivity

Input/output terminals including EXT CLOCK, MEMORY I/O, and power connectors.

OPERATING THE INSTRUMENT

Basic Oscilloscope and Memory Setup

Setting up for standard viewing and initial digital memory configuration.

Waveform Storage and Readout

Using DELAY, pen recorder, and automatic free-run for data acquisition.

Signal Measurement Techniques

Measuring input signal voltage and time using the instrument.

INSTRUMENT APPLICATIONS AND USE CASES

Digital Memory Scope Applications

Analyzing transient phenomena, electrical circuits, and relay chattering.

Waveform Recording and Analysis

Using pen recorders for data logging and applying X-Y measurements.

Amplifier Performance Testing

Evaluating amplifier response using square wave signals for distortion analysis.

SAFETY AND HANDLING PRECAUTIONS

Environmental and Electrical Safety

Guidelines for installation location, voltage limits, and avoiding shocks.

Operational Safety Measures

Proper use of controls like INTENSITY, ventilation, and grounding.

MAINTENANCE AND ADJUSTMENT PROCEDURES

Unit Maintenance Procedures

Steps for accessing internal components for cleaning or inspection.

Calibration and Adjustment Steps

Adjusting DC BAL and Vertical Attenuator for optimal performance.

ACCESSORIES AND OPTIONS

Unit Combination and Interfacing

Connecting the MS-1650B with MU-1651 using a joiner kit.

Accessory Bag Installation

Steps for attaching the optional accessory bag for portability.