OWNER'S MANUAL
IMPORTANT: READ OWNER'S MANUAL CAREFULLY
MODEL
Ultron 20BA
Ultron 20TD
Ultron 20TO
8130052
REV.01(07-2018)

Questions and Answers

  • B
    Brenda CarpenterAug 9, 2025
    What to do if my Triple S Ultron 20TO has poor water pick up?
    • K
      katherine17Aug 9, 2025
      If the Triple S Ultrasonic Jewelry Cleaner isn't picking up water effectively, it might be due to several reasons. First, check if the recovery tank is full and needs draining. Ensure the drain hose cap is tightened. Inspect the float shut-off screen in the recovery tank and the squeegee assembly for clogs, cleaning them if necessary. Examine the squeegee blades for wear and replace or rotate them as needed. Adjust the squeegee blade height if the deflection is incorrect. Secure any loose vacuum hose connections and clear any blockages in the vacuum hose. If the vacuum hose is damaged, replace it. Make sure the recovery tank cover is properly positioned and that the seal isn't damaged; replace the seal if needed. Also, check the battery charge level and recharge if low.
  • D
    Danny CarsonAug 17, 2025
    Why won't my Triple S Ultron 20TO operate?
    • J
      Jo ChristianAug 18, 2025
      If your Triple S Ultrasonic Jewelry Cleaner machine won't operate, there are several potential causes. Ensure the control handle bail is fully pulled. Check the batteries; they may need charging or replacing. Also, verify the battery connections are secure and tightened. Inspect the main control unit for a tripped circuit breaker and reset it if necessary.
  • N
    nicole33Aug 25, 2025
    How to fix little or no solution flow in my Triple S Ultron 20TO?
    • A
      Andrew ThompsonAug 25, 2025
      If you're experiencing little to no solution flow in your Triple S Ultrasonic Jewelry Cleaner, start by checking the ball valve to ensure it's fully open. Next, verify that the solution flow control knob is properly adjusted and not set too low or shut off. Inspect the solution tank filter and solution hose for any clogs, cleaning or flushing them as needed. Lastly, check the solution solenoid valve for clogs and clean it if necessary.
  • J
    jeffreyramosAug 31, 2025
    Why does my Triple S Ultron 20TO Ultrasonic Jewelry Cleaner have a short run time?
    • J
      Jason SmithAug 31, 2025
      If your Triple S Ultrasonic Jewelry Cleaner has a short run time, the issue could stem from a few sources. Begin by fully recharging the batteries. If the problem persists, the batteries might be defective and need replacing. Additionally, inspect the battery charger for any faults, repairing or replacing it as necessary. Check the down pressure lever and lower it if it's set for extra scrub head pressure.

Summary

Safety Precautions

Machine Components

Panel Components

Machine Set Up & Installation

Pre-Operation Checks

Key checks to perform before starting the machine.

Installing Batteries

Guide to connecting the machine's batteries correctly.

Filling the Solution Tank

Machine Operation

While Operating Machine

Circuit Breaker

Tank Draining

Battery Charging

Preventative Maintenance

Daily Maintenance

Fault Code & Solution

Basic Troubleshooting

Technical Specifications

Wear and Tear Parts

Wiring Diagram (Ultron 20 BA)

Wiring Diagram (Ultron 20 TD & Ultron 20 TO)

Triple S Ultron 20TO Specifications

General IconGeneral
BrandTriple S
ModelUltron 20TO
CategoryUltrasonic Jewelry Cleaner
LanguageEnglish