Safety
This symbol, adjacent to another symbol or terminal, indicates the user must
refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use,
hazardous voltages may be present
Double insulation
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Make sure any covers or battery doors are properly closed and secured.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before
operating the meter. Repair any damage before use.
Do not exceed the maximum rated input limits.
Use great care when making measurements if the voltages are greater than 25VAC
rms or 35VDC. These voltages are considered a shock hazard.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
Remove the battery from the meter if the meter is to be stored for long periods.
To avoid electric shock, do not measure AC current on any circuit whose voltage
exceeds 250V AC.
Safety standards
Design standards
EN61010-1: 2010;
EN61010-2-030:2010;
EN 61326-1:2013
EN61010-2-033:2012,EN61326-2-2:2013
EMC
RF field (1V/m): Overall accuracy = specified accuracy ± 5% of range
RF field (>1V/m): No specified
calculation
Measurement
standards
CAT
III 600V,
double insulation and
material pollution degree II
Dimensions
130mm×65mm×28mm
Weight
About 130g (including batteries)