Once the calibration download has been started, do not switch the ignition or engine
Start/Stop switches to a different position unless instructed to do so by the Triumph
Diagnostic Tool/download process flow chart.
Do not disconnect the diagnostic interface during the calibration download.
During a calibration download, multiple files are downloaded and the progress bar
displayed will repeatedly rise from 0% to 100% as each file is downloaded. Always wait
for the Verifying Download screen to appear to confirm that the full calibration has
downloaded successfully and click the Finish button to end the process. Do not click
the Cancel button while the download is still in progress.
Instrument Calibration Downloads
Following an instrument calibration download, the following items (if fitted) may return
to their factory default settings. Before starting an instrument calibration download,
record the settings of each item where applicable so that the settings can be restored
after the download has finished.
• Time/date
• Distance/time to next service
• TPMS instrument display (enabled/disabled)
• All riding mode settings
• Self cancelling indicators (enabled/disabled).
Downloading Sequence - Calibration Downloads to Multiple ECMs
When planning to download a calibration, check each of the motorcycle's ECMs for out
of date calibrations and make sure all ECMs are updated as necessary. Where calibration
updates are available for more than one ECM, the ECMs should be updated in the
following order.
1. Keyless ECM
2. Chassis ECM
3. Suspension ECM
4. Headlight ECM
5. Blind spot radar ECM
6. Instruments
7. Engine ECM