6. Fuzzy Logic Mode
a ). Fuzzy Logic mode counters rising or falling
CO2 levels by quickly activating the CO2 solenoid
valve, allowing CO2 levels to be controlled more
precisely.
b ). The Fuzzy Logic function is active if the Fuzzy
Logic LED indicator illuminated.
c ). Factory default setting of fuzzy logic is off. To
activate the fuzzy logic, press HOME button
5 times, the Fuzzy Logic LED indicator
will be blinking. Press UP or DOWN , the
LED display OFF. Press or , the LED
displays ON. Press HOME button to confirm and
activate the fuzzy logic and the Fuzzy Logic LED
indicator will illuminate.
d ). This function can be used ONLY with
compressed CO2.
e). Do not use Fuzzy Logic with a CO2 generator !
! !