15
2). When the Device 1 is selected, user can set the CO2 setpoint during Daytime for the Device 1. The unit
will automatically turn ON the CO2 Device 1 when the measured CO2 level is ABOVE or BELOW the setpoint.
Press ENTER button and the Above or Below text will be flashing. Press UP or DOWN button to change
between Above and Below. Finally, press ENTER button to confirm and save the change. The LCD screen will
display “Setting saved".
For example: Turn on device when CO2 level reaches the Above setpoint for Exhaust fan; Turn on device
when CO2 level reaches the Below setpoint forCO2 Generator or Regulator.
User can set the setpoint for Day mode. Press DOWN button to select the CO2 value. Press ENTER button
and the current CO2 value will be flashing. Press UP or DOWN to change the CO2 setpoint with the
increment of 10. Finally, press ENTER button to confirm and save the change.
User can also turn ON or OFF the Fuzzy Logic mode. Press DOWN button to select the Fuzzy subject and
then press ENTER button. The ON or OFF text will be flashing. Then press UP or DOWN button to change
between ON and OFF status. Finally, press ENTER button to confirm and save the change.
*NOTE:
1) Fuzzy Logic mode is only for the control of CO2 Regulator. Do not turn on while connecting to a CO2
generator.
2) Fuzzy Logic mode counters rising or falling CO2 levels by quickly activating the CO2 selenoid valve,
allowing CO2 levels to be controlled more precisely.
3). Press DOWN button to select and enter the CO2 Alarm page. The screen will display the Min / Max
setpoint. Press UP or DOWN button to select the Min or Max setpoint. The selected item will be highlighted.