11 EN
dehumidifier TTK 96 E / TTK 127 E
Emptying the condensation tank
If the condensation tank is full or not inserted correctly, the Full
LED(17) lights up the the message P2 appears on the display.
Compressor and fan will switch off.
1. Take the condensation tank out of the device.
2. Empty the condensation tank over a drain or sink.
3. Rinse the tank with clear water. Clean the tank regularly
using a mild cleaning agent (no detergent!).
4. Refit the condensation tank into the device. In doing so,
make sure that the condensation tank is inserted correctly,
for otherwise the device cannot be switched back on.