Page #7 background imageLoading...
Page #7 background image
EN 6
dehumidifier TTK 96 E / TTK 127 E
Operation
After being switched on, the device operates fully
automatically.
The fan is running continuously until the device is switched
off.
Avoid open doors and windows.
Operating elements
On
Off
Full
Auto defrost
13 14 17 18 19 20
212223242526
15 16
27
No. Designation Meaning
13 FILTER LED Illuminated when the filter needs to
be cleaned.
14 Auto defrost LED Illuminated when the device carries
out an automatic defrost.
15 CONT. LED Illuminated when the device runs in
continuous operation.
16 TURBO LED Illuminated when the fan runs at
maximum power.
17 FULL LED Illuminated when the condensation
tank is full. See chapter Emptying the
condensation tank
18 Off LED Illuminated when the timer is
programmed for automatic switch-
off.
19 On LED Illuminated when the timer is
programmed for automatic switch-
on.
20 Display Indicates the current humidity level.
Indicates the selected humidity value
during the humidity setting.
Indicates the number of hours during
the timer setting.
21 POWER button Switches the device on or off.
22 Selection button Selection button for the humidity level
(35% to 85% in increments of 5%)
or the timer function (0 to 10h in
increments of 0.5hours or 10 to 24h
in increments of 1h)
No. Designation Meaning
23 TIMER button Switches the timer function on or off.
24 TURBO button Sets the fan stage.
Stage 1 = normal
Stage 2 = function for drying laundry
25 CONT. button Switches continuous operation on or
off.
26 FILTER button Resets the cleaning cycle for the
filter.
27 COMFORT button Switches comfort mode on or off.
Inserting the air filter
Make sure that the air filter is installed before switching the
device on.
The device should not be operated without air filter. Without air
filter the inside of the device will be heavily contaminated,
which affects the dehumidification performance adversely and
may further result in damage to the device.
Switching the device on
1. Ensure that the condensation tank is empty and inserted
correctly.
2. Insert the mains plug into a properly secured mains
socket.
3. Press the POWER button(21).
Setting the humidity level
You can adjust the preset humidity level at any time during
operation.
1. Press the left or right-hand side of the selection button(22)
to adjust the desired humidity level.
ð The desired humidity level will be indicated on the
display(20) for approx.5s.
ð Then the currently measured humidity level reappears on
the display.
ð The device switches off automatically upon reaching the
desired humidity level.
Setting the fan stage
1. Press the TURBO button(24) to switch between the normal
and maximum fan stage.
ð The TURBO LED(16) is illuminated when the fan runs at
maximum power.