EasyManuals Logo

Trotec TTK 127 E User Manual

Trotec TTK 127 E
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
EN 12
dehumidifier TTK 96 E / TTK 127 E
Technical annex
Technical data
Parameter Value
Model TTK96E TTK 127 E
Max. dehumidification performance 30 l / 24 h 50 l / 24 h
Dehumidification performance @ 30°C
and 80%RH
28.3 l / 24 h 46.8 l / 24 h
Air volume [m
3
/h] stage1: 180
stage2: 210
stage1: 320
stage2: 345
Ambient temperature 5°C - 35°C 5°C - 35°C
Operating range relative humidity 35 % - 100 % RH 35 % - 100 % RH
Pressure suction side 1.5MPa 1.5MPa
Pressure outlet side 4.2MPa 4.2MPa
Mains connection 1/N/PE~ 230 V / 50 Hz 1/N/PE~ 230 V / 50 Hz
Power consumption 465 W 775 W
Nominal current 2.5 A 3.6 A
Refrigerant R-410A R-410A
Amount of refrigerant 220 g 290 g
GWP factor 2,088 2,088
CO
2
equivalent 0.459 t 0.606 t
Condensation tank 3 l 6 l
Sound pressure level 52 dB (A) 51 dB (A)
Dimensions (length x width x height) 386 x 260 x 500 (mm) 392 x 282 x 616 (mm)
Minimum distance to walls and other
objects
top: 40 cm
front: 20 cm
rear: 20 cm
right: 20 cm
left: 40 cm
top: 40 cm
front: 20 cm
rear: 20 cm
right: 20 cm
left: 40 cm
Weight 15 kg 20 kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trotec TTK 127 E and is the answer not in the manual?

Trotec TTK 127 E Specifications

General IconGeneral
BrandTrotec
ModelTTK 127 E
CategoryOther
LanguageEnglish