EasyManua.ls Logo

Truma GS 10 - Technical Data

Truma GS 10
56 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Technical data
LPG flow rate
with 2.5 mbar pressure drop
(20 °C / 30 mbar)
GSE: 1.0 kg/h
GS 8: 1.5 kg/h
GS 10: 2.0 kg/h
Inlet connection
GSE: 1/4" left union nut
GS 8: Journal Ø 8 mm
GS 10: Journal Ø 10 mm
Outlet connection
GSE: 1/4" left male thread
GS 8: Male thread, olive screw
connection
Ø 8 mm
GS 10: Male thread, olive screw
connection
Ø 10 mm
Max. pressure
150 mbar
Nominal voltage
12 V DC
Power consumption
40 mA
brief (open) 2 A
Protection class
IP 54
Product ID number
GSE: CE-0085AQ0898
GS 8 / GS 10: CE-0085AS0506
Ambient temperature
-30 °C to +60 °C
Opening and closing time
< 0.1 s
Installation position
any
Dirt sieve
integrated in the gas input.
Valve class
A
Control unit group
2
II 3 G Ex nA II T6
The gas remote switch is suit-
able for operation and installation
in Zone II (e.g. cylinder boxes)
in an area with a potential ex-
plosion risk in accordance with
the ATEX directive 94/9/EC
. The
control panel is not suitable for
installation in Zone II.