Function check
After installation, the gas feed line must be tested for tight-
ness by the pressure-drop method. A test certificate (in Ger-
many, for example, in accordance with DVGW Worksheet
G 607 for motor vehicles or G 608 for boats) is to be issued.
All equipment functions must be tested in accordance with
the user manual after installation.
The operating instructions and completed guarantee card are
to be given to the owner of the vehicle.
Remove the type plate from the operating and installa-
tion instructions and affix it at a position on the heater
which is clearly visible and well protected against damage.
The year of initial operation must be marked on the type plate.
Warning information
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the
appliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.