Maximum measurement in voltage drop: 200 mV
Input maximum current: 20 A (The test time shall be between 10 seconds).
Frequency response: (40 – 1 000) Hz (for standard sine wave and
triangular wave)
Display: Real RMS (only as reference when is over 200 Hz in other waves)
AC CURRENT
Overload protection: 250 V RMS
When using automatic recuperation fuses after the external fault is
eliminated. the fuse turns back to normal and the multimeter can be used
normally.
Maximum measurement in voltage drop: 200 mV
Input maximum current: 20 A (test time shall be within 10 seconds)
Frequency response: (40 – 1 000) Hz (for standard sine wave and
triangular wave)
Display: True RMS (only as reference when over 200 Hz in other waves)
RESISTANCE (auto fluctuating)
Overload protection: 250 v DC and AC peak value.
In 200 Ω range, the test probes shall be set in short circuit to measure the
own resistance of the probes and then, this value shall be deducted from
the final measurement.
For safety reasons, DO NOT ENTER any voltage in the resistance range.
Range Resolution Precision
200 Ω 0,1 Ω
2 kΩ 1 Ω
20 kΩ 10 Ω (1,5% de rdg + 3 dgts)
200 kΩ 100 Ω
2 MΩ 1 kΩ
20 MΩ 10 kΩ (1,5% de rdg + 5 dgts)
WARNING!
NOTE
Range Resolution Precision
200 mA 100 µA (1,5% de rdg + 10 dgts)
20 A 10 mA (2,0% de rdg + 10 dgts)