14
Status Codes
During setup and operation the status light on the wall plate will provide information
regarding system function. The following list will help to understand the different
conditions indicated:
Flashing Red – This indicates the following:
1. Upon powerup - This indicates that the dip switches have not been set correctly.
(See Step 11)
2. During motor operation – It indicates that the motor has run into an obstruction or
that the window/skylight hardware requires service. The motor is seeing too high
an operating load.
3. Upon pressing an “open” or “close” button on the remote – This indicates that the
control did not receive a complete command. You may need to move closer with
the remote and/or repeat the command. Check battery status on remote.
Solid Red – This indicates the following:
1. During Installation – This indicates that the dip switches are set correctly but the
motor needs to be initialized by pressing the open button on the wall switch or
remote.
2. During motor operation – The motor is running through initialization to learn the
range of motion.
Solid Green – This indicates normal motor operation and should only be lit while motor
is in operation.
Flashing Green – This indicates the Rain sensor has detected rain or moisture and is
closing the window/skylight.