Check the Installation Environment and Position
Installation Steps
Step 1. Fix the microinveer Step 2. Connect the AC cable
DANGER
DANGER
WARNING
CAUTION
TITAN MICROINVERTER
Quick Installation
When choosing the position of installation, comply with the following
conditions:
Choose an installation position. Using two pairs of screws and nuts
to x the microinveer on the frame. Make sure that the label of
microinveer should be upside.
Take out the AC connector from the package. Get the AC cable
through the shell of AC connecter and connect the cable to the
right po.
The denition of the po is shown below:
Microinveer can also be installed on the wall. Using the bracket
(optional) and x it on the wall. Then using two pairs of screws and
nuts to x the microinveer on the bracket. Make sure that the
label of microinveer should be outside.
· To avoid unwanted power derating due to an increase in the
internal temperature of the inveer, do not expose it to direct
sunlight.
· To avoid overheating, always make sure the ow of air around the
inveer is not blocked.
· Do not install in places where gasses or ammable substances
may be present.
· Avoid electromagnetic inteerence that can compromise the
correct operation of electronic equipment.
· It’s recommended to install microinveer on structures under-
neath the photovoltaic modules so that they work in the shade.
· Use a mobile phone to check the Wi-Fi signal strength at the
installation position. If the Wi-Fi signal is bad, t to install the
microinveer at another position or move the Wi-Fi router.
Only qualied personnel should install, troubleshoot, or replace TITAN
micro inveers or the cable and accessories.
·Before installation, check the unit to ensure absence of any transpo
or handling damage, which could aect insulation integrity or safety
clearances.
·Unauthorized removal of necessa protections, improper use,
incorrect installation and operation may lead to serious safety and
shock hazards or equipment damage.
·Be aware that installation of this equipment includes risk of electric
shock.
Do not install the equipment in adverse environment conditions such
as ammable, explosive, corrosive, extreme high or low temperature,
and humid.
Choose installation location carefully and adhere to specied cooling
requirements. Micro-inveer should be installed in a suitable position
with good ventilation and no directly sunshine.
There are no screws and nuts in the package.
DANGER
WARNING
CAUTION
·Do not install the AC junction box without rst removing AC power
from the system.
·To prevent electrical hazards, make sure the micro-inveer system is
disconnected from the home distribution network and the AC breaker
is open.
·Ensure that all AC cables are correctly wired and that none of the
wires are pinched or damaged.
·Use AWG 12 ( 4 mm²) cable for AC end cable.
·The installation technician is responsible for selecting a kind of AC
cable and connecting the micro-inveer system into the home
distribution network correctly.
·The AC connecters may be provided by dierent suppliers. The po
denitions are subject to actual objects.
L: Live (Brown/Red)
N: Neutral (Blue/Black)
PE: Ground (Yellow-Green)